grav/pages/11.ro-system/docs.md

2.5 KiB

title
RO System

Flow of water:

  1. Filter 1 - Sediment filter
  2. Filter 2 - GAC Filter (Granulated Activated Carbon Filter)
  3. Filter 3 - CTO Filter (Clorine, Taste and Odour Control)
  4. Low pressure switch
  5. Solenoid
  6. Input for TDS Adjuster
  7. Membrane -> Flow restrictor on the drain
  8. Merge back TDS Adjuster
  9. T-Connector which goes to the Pressure Tank
  10. High pressure switch to turn off the RO When the tank is full.
  11. Post Carbon Filter
  12. UV Filter
  13. Output at 30-40 PSI as set in the Pressure Tank

TDS Adjuster will make sure that we have TDS in range that we want. It can be adjusted according to our need. Chandigarh is making nice hard ice. We should check the TDS there and make sure that the water we use has the same TDS. 150 GPD Membrane (AXEON Maybe) Check initial TDS AXEON HIGH REJECTION (HR) 150 GPD MEMBRANE + LEFOO 100 GPD @ 3000+ TDS LIVE TEST 1600 mlm flow restrictor (restrictor mlm * .38 / 4 = Membrane GPD) Check A Solenoid valve before the membrane 150 GPD pump Check all the filters UV Filter TDS Adjuster to control the TDS (Input from before the membrane and output to after the membrane but before the uv filter) Sample Pressure tank after (35L should be fine) Option 1 Option 2 Option 3

line after uv tank T to ro and outlet and a high pressure switch there to turn off the ro when the pressure is high. then a T ... one to the ice machine and other to the water tank

this will take care of the RO for both

Pressure should be around 45 psi (The Ice machine requires 14-70 psi Scotsman 606) .... but with the pump, that should not be an issue 7972197566 Reviewmaza Prasad Jhadav

300GPD will give 40 Ltrs / hr and is also a good idea for upgrade to the basement RO. Only the Pump and RO needs to be upgraded

Clean and sanitize Ice Machine every 4 months

Electrical Connections

  1. Mains into the SMPS
  2. Pump and Solenoid together into the SMPS out
  3. Low Pressure (LP) switch between the SMPS out Live (Red) and the Pump/solenoid to cut out pump in case of no input water
  4. High Pressure (HP) switch between the LP coutout and the Pump/solenoid to stop the pump once the output tank is pressurized