title: 'RO System'
---
Flow of water:
1. Filter 1
2. Filter 2
3. Filter 3
4. Low pressure switch
5. Solenoid
6. Input for TDS Adjuster
7. Membrane -> Flow restrictor on the drain
8. Merge back TDS Adjuster
9. T-Connector which goes to the Pressure Tank
10. High pressure switch to turn off the RO When the tank is full.
11. Post Carbon Filter
12. UV Filter
13. Output at 30-40 PSI as set in the Pressure Tank
150 GPD Membrane (AXEON Maybe) Check initial TDS
https://www.youtube.com/watch?v=-kc6B9lx7M4
1600 mlm flow restrictor (restrictor mlm * .38 / 4 = Membrane GPD)
Check A Solenoid valve before the membrane
150 GPD pump
Check all the filters
UV Filter
TDS Adjuster to control the TDS (Input from before the membrane and output to after the membrane but before the uv filter)
https://www.amazon.in/PARIJATA-Water-Purifier-TDS-Adjuster/dp/B071GYQN8F/ref=sr_1_3?crid=14JSQBCO3GK9Y&keywords=tds+adjuster&qid=1563217638&s=gateway&sprefix=batteries+%2Caps%2C281&sr=8-3
Pressure tank after (35L should be fine)
https://www.autoconindia.in/pressure-tank.html
https://www.aventura.co.in/pressure_boosting_tanks.html
https://www.industrybuying.com/pumps-1160/pressure-tank-4421/
line after uv tank T to ro and outlet and a high pressure switch there to turn off the ro when the pressure is high. then a T ... one to the ice machine and other to the water tank
this will take care of the RO for both
Pressure should be 60 + .... but with the pump, that should not be an issue