@ -44,3 +44,10 @@ Pressure should be around 60 psi (The Ice machine requires 20-80 psi Manitowoc a
|
||||
300GPD will give 40 Ltrs / hr and is also a good idea for upgrade to the basement RO. Only the Pump and RO needs to be upgraded
|
||||
|
||||
**Clean and sanitize Ice Machine every 4 months**
|
||||
|
||||
### Electrical Connections
|
||||
|
||||
1. Mains into the SMPS
|
||||
2. Pump and Solenoid together into the SMPS out
|
||||
3. Low Pressure (LP) switch between the SMPS out Live (Red) and the Pump/solenoid to cut out pump in case of no input water
|
||||
4. High Pressure (HP) switch between the LP coutout and the Pump/solenoid to stop the pump once the output tank is pressurized
|