@ -53,4 +53,9 @@ Pressure should be around 45 psi (The Ice machine requires 14-70 psi Scotsman 60
|
|||||||
3. Low Pressure (LP) switch between the SMPS out Live (Red) and the Pump/solenoid to cut out pump in case of no input water
|
3. Low Pressure (LP) switch between the SMPS out Live (Red) and the Pump/solenoid to cut out pump in case of no input water
|
||||||
4. High Pressure (HP) switch between the LP coutout and the Pump/solenoid to stop the pump once the output tank is pressurized
|
4. High Pressure (HP) switch between the LP coutout and the Pump/solenoid to stop the pump once the output tank is pressurized
|
||||||
|
|
||||||
![5 Stage](ro-102p-1.jpg)
|
### 5 Stage RO With
|
||||||
|
1. Low Pressure Switch
|
||||||
|
2. High Pressure Switch
|
||||||
|
3. Water Tank
|
||||||
|
4. TDS Adjuster
|
||||||
|
![](ro-102p-1.jpg)
|